Centrifugal Fan
BC220 Series — Backward-Curved Centrifugal Fans
Applications
220 mm backward-curved centrifugal fans covering 920–1,180 m³/h at 590–815 Pa — pressure for long duct runs, HEPA stages and ERV cores. One frame, three motor schemes: AC fixed-speed, DC (24 V wide-range, 115 V) and EC (0-10V/PWM). IP54.
Selection notes
The BC220 range covers 6 models between 920–1180 m³/h, with static pressure up to 815 Pa. Motor options are AC / DC / EC; speed is set through 3-speed, 0-10V/PWM, Modbus RTU(RS485).
For system design this means one construction principle across the whole envelope, so installations with a similar air demand can be resolved without switching fan family. For the destination market the grid is typically 110–240 V, 50/60 Hz, with CE, UL/ETL or CCC depending on destination as the compliance framework.
| Model | Voltage | Power | Airflow | Noise | Speed Control | View Details |
|---|---|---|---|---|---|---|
| BC220A-A092C1-02 | 115 VAC | 105 W | 920 m³/h | 71±2 dB(A) | 3-speed |
| Model | Voltage | Power | Airflow | Noise | Speed Control | View Details |
|---|---|---|---|---|---|---|
| BC220A-D092A6-01 | 24 V DC [16-28VDC] | 100 W | 960 m³/h | 73±2 dB(A) | 0-10V/PWM |
| Model | Voltage | Power | Airflow | Noise | Speed Control | View Details |
|---|---|---|---|---|---|---|
| BC220B-E072A1-01 | 115 V AC | 60 W | 920 m³/h | 68 dB(A) | 0-10V/PWM, 3-speed | |
| BC220B-E072B3-01 | 230 V AC | 120 W | 1060m³/h | 70 dB(A) | 0-10V/PWM, 3-speed | |
| BC220B-E092D1-02 | 115 V AC | 120 W | 1060m³/h | 70 dB(A) | 0-10V/PWM, Modbus RTU(RS485) | |
| BC220B-E092D3-02 | 230 V AC | 160 W | 1180 m³/h | 75 dB(A) | 0-10V/PWM, Modbus RTU(RS485) |
Compare Models
Select up to 4 models to compare detailed specifications. Each parameter row is color-coded.
FAQ
BC220A-A092C1-02
The BC220 comes in AC, DC and EC — how do I pick one?
AC: fixed-speed or 3-speed duty where nothing modulates and cost rules.
AC: fixed-speed or 3-speed duty where nothing modulates and cost rules. DC (24 V wide-range, 115 V): battery or vehicle power. EC (0-10V/PWM): anything that modulates. All three share the 220 mm frame and mounting, so you can prototype with one motor technology and production-order another without redesigning the chassis.
What kind of duct system actually needs 590–815 Pa?
Pressure budgets add up fast: a HEPA terminal alone eats 250–400 Pa at face velocity, an ERV core 100–200 Pa, and every meter of duct and each bend adds its share. Total a filtration stage, a recovery core and a 10 m run, and 600 Pa is gone. The BC220’s 920–1,180 m³/h at up to 815 Pa is sized for exactly such resistance-heavy paths.
My fan got noticeably louder after commissioning — what moved?
Almost always the operating point.
Almost always the operating point. If a damper was opened or a filter section was left out, the fan ran out along its curve toward free air — where backward-curved fans get loud. Re-check the system curve against the fan curve and confirm the point still sits right of the pressure peak. If it drifted left of peak, add resistance back or reduce speed; running in the unstable valley causes noise and vibration.