Guides
Application Guides & Selection Resources
Industry application pages, selection guides and comparisons that map SUNXFAN fans to real-world use cases.
PDF matcher
Find the PDF for your model
Type a model or series code (e.g. SF146A-E092A3-02), narrow by category or airflow, and download the matching PDF datasheet. All 121 model datasheets are hosted on this site and updated in place.
121 models listed · datasheets update in place
| Model | Series | Airflow | Max static pressure | Power | |
|---|---|---|---|---|---|
| AF300A-E092A3-01 | AF Axial-Fan Guard | 2200 m³/h | 180 Pa | 165 W | |
| AF300D-A092A3-01 | AF Axial-Fan Guard | 1750 m³/h | 180 Pa | 75 W | |
| AF400D-A106A3-01 | AF Axial-Fan Guard | 3600 m³/h | 180 Pa | 180 W | |
| AF500D-A106C3-01 | AF Axial-Fan Guard | 7050 m³/h | 180 Pa | 410 W | |
| AF600D-A137A3-01 | AF Axial-Fan Guard | 10000 m³/h | 300 Pa | 700 W | |
| AG200A-D092BA-01 | 800VDC Axial-Fan | 1950 m³/h | 1550 Pa | 800 W | |
| AG200B-D092A6-03 | AG Axial- Flange | 1100 m³/h | 500 Pa | 120 W | |
| AG250B-D092A0-01 | AG Axial-Fan Flange | 1950 m³/h | 300 Pa | 140 W | |
| AG250C-E072B3-03 | AG Axial- Flange | 1850 m³/h | 300 Pa | 120 W | |
| AG305A-D092BA-Y1 | 800VDC Axial-Fan | 4000 m³/h | 750 Pa | 1200 W | |
| AG400A-D092BA-02 | 800VDC Axial-Fan | 9000 m³/h | 850 Pa | 1500 W | |
| AS760A-E137A3-01 | AS Axial-Fan Integrated Guard Ring | 16500 m³/h | 300 Pa | 1100 W | |
| AS860A-E150A3-01 | AS Axial-Fan Integrated Guard Ring | 24000 m³/h | 300 Pa | 1800 W | |
| AS910A-E150A3-01 | AS Axial-Fan Integrated Guard Ring | 25000 m³/h | 300 Pa | 1800 W | |
| AS960A-E150B3-01 | AS Axial-Fan Integrated Guard Ring | 29000 m³/h | 300 Pa | 3200 W | |
| BC133A-E072A1-01 | BC133 | 450 m³/h | 500 Pa | 50 W | |
| BC133A-E072A3-01 | BC133 | 450 m³/h | 500 Pa | 50 W | |
| BC133A-E072D1-01 | BC133 | 450 m³/h | 500 Pa | 50 W | |
| BC133A-E072D3-01 | BC133 | 480 m³/h | 580 Pa | 70 W | |
| BC175B-D061B8-01 | BC175 | 540 m³/h | 360 Pa | 40 W | |
| BC175B-E072A1-01 | BC175 | 540 m³/h | 415 Pa | 50 W | |
| BC175B-E072A3-01 | BC175 | 680m³/h | 615 Pa | 90 W | |
| BC175B-E072D1-01 | BC175 | 680 m³/h | 615 Pa | 90 W | |
| BC175B-E072D3-02 | BC175 | 780m³/h | 770 Pa | 120 W | |
| BC190A-D072A8-01 | BC190 | 620 m³/h | 500 Pa | 58 W | |
| BC190B-D072A6-01 | BC190 | 660 m³/h | 500 Pa | 70 W | |
| BC190B-E072A1-01 | BC190 | 530 m³/h | 590 Pa | 60 W | |
| BC190B-E072A3-42 | BC190 | 530 m³/h | 590 Pa | 60 W | |
| BC190B-E072B3-02 | BC190 | 780m³/h | 770 Pa | 120 W | |
| BC190B-E072D1-02 | BC190 | 660 m³/h | 590 Pa | 90 W | |
| BC220A-A092C1-02 | BC220 | 920 m³/h | 590 Pa | 105 W | |
| BC220A-D092A6-01 | BC220 | 960 m³/h | 590 Pa | 100 W | |
| BC220B-E072A1-01 | BC220 | 920 m³/h | 605 Pa | 60 W | |
| BC220B-E072B3-01 | BC220 | 1060m³/h | 605 Pa | 120 W | |
| BC220B-E092D1-02 | BC220 | 1060m³/h | 605 Pa | 120 W | |
| BC220B-E092D3-02 | BC220 | 1180 m³/h | 815 Pa | 160 W | |
| BC225A-A092C2-01 | BC225 | 1100/890/750 m³/h | 500 Pa | 120/95/87 W | |
| BC225A-D072A6-01 | BC225 | 1150 m³/h | 560 Pa | 100 W | |
| BC225A-D092A0-01 | BC225 | 1250 m³/h | 660 Pa | 120 W | |
| BC225A-E072B3-01 | BC225 | 1200 m³/h | 550 Pa | 90 W | |
| BC225A-E092D1-02 | BC225 | 1420 m³/h | 690 Pa | 165 W | |
| BC225A-E092D3-02 | BC225 | 1420 m³/h | 690 Pa | 165 W | |
| BC225B-D092A8-01 | BC225 | 1150 m³/h | 560 Pa | 99 W | |
| BC225B-E072A3-03 | BC225 | 1020 m³/h | 495 Pa | 70 W | |
| BC225B-E072E1-01 | BC225 | 1020 m³/h | 550 Pa | 100 W | |
| BC250A-A092D3-01 | BC250 | 1400/1800 m³/h | 615 Pa | 175/230 W | |
| BC250A-D092A8-01 | BC250 | 1450 m³/h | 760 Pa | 160 W | |
| BC250A-E072B3-01 | BC250 | 1080 m³/h | 590 Pa | 120 W | |
| BC250A-E092D1-01 | BC250 | 1080 m³/h | 740 Pa | 125 W | |
| BC250A-E092D3-02 | BC250 | 1420 m³/h | 740 Pa | 160 W | |
| BC250A-E092E1-02 | BC250 | 1420 m³/h | 740 Pa | 160 W | |
| BC250A-E092E3-03 | BC250 | 1680 m³/h | 750 Pa | 240 W | |
| BC280A-E092D1-01 | BC280 | 1540 m³/h | 550 Pa | 125 W | |
| BC280A-E092D3-01 | BC280 | 1540 m³/h | 715 Pa | 125 W | |
| BC280A-E092E1-02 | BC280 | 1800 m³/h | 715 Pa | 220 W | |
| BC280A-E092E3-02 | BC280 | 1800 m³/h | 715 Pa | 200 W | |
| BC280B-E092E3-02 | BC280 | 2000 m³/h | 460 Pa | 200 W | |
| BC310A-E092D1-01 | BC310 | 1950 m³/h | 715 Pa | 160 W | |
| BC310A-E092D3-01 | BC310 | 2100 m³/h | 715 Pa | 160 W | |
| BC310A-E092E3-02 | BC310 | 2500 m³/h | 715 Pa | 240 W | |
| BC310B-E092E1-01 | BC310 | 1750 m³/h | 615 Pa | 175 W | |
| BC310B-E092E3-01 | BC310 | 2500 m³/h | 615 Pa | 175 W | |
| DG120A-E072A1-01 | DG120 | 300 m³/h | 405 Pa | 50W | |
| DG120A-E072A3-01 | DG120 | 300 m³/h | 405 Pa | 50W | |
| DG120B-E072A1-02 | DG120 | 380 m³/h | 605 Pa | 85 W | |
| DG120B-E072A3-02 | DG120 | 380 m³/h | 605 Pa | 85 W | |
| DG120C-E072A1-01 | DG120 | 300 m³/h | 405 Pa | 50W | |
| DG120C-E072A1-02 | DG120 | 365 m³/h | 405 Pa | 80W | |
| DG120C-E072A3-01 | DG120 | 300 m³/h | 405 Pa | 50W | |
| DG120C-E072A3-02 | DG120 | 365 m³/h | 405 Pa | 80W | |
| DG140A-D072A6-01 | DG140 | 430 m³/h | 410 Pa | 60 W | |
| DG140A-D092A0-01 | DG140 | 430 m³/h | 410 Pa | 100 W | |
| DG140A-E072A1-01 | DG140 | 380 m³/h | 460 Pa | 60 W | |
| DG140A-E072A3-01 | DG140 | 380 m³/h | 460 Pa | 60 W | |
| DG140B-E072D1-01 | DG140 | 460 m³/h | 460 Pa | 100 W | |
| DG140B-E072D3-01 | DG140 | 460 m³/h | 460 Pa | 100 W | |
| DG160A-E072B1-01 | DG160 | 530 m³/h | 590 Pa | 80 W | |
| DG160A-E072B3-01 | DG160 | 530 m³/h | 590 Pa | 80 W | |
| DG160B-E092D1-02 | DG160 | 680 m³/h | 680 Pa | 150 W | |
| DG160B-E092D3-02 | DG160 | 680 m³/h | 680 Pa | 150 W | |
| DG180A-E092E1-01 | DG180 | 960 m³/h | 360 Pa | 175 W | |
| DG180A-E092E3-01 | DG180 | 960 m³/h | 360 Pa | 175 W | |
| DG180B-E092D1-01 | DG180 | 780 m³/h | 330 Pa | 120 W | |
| DG180B-E092D3-01 | DG180 | 780 m³/h | 330 Pa | 120 W | |
| DG200D-D092B0-01 | DG200 | 1050 m³/h | 305 Pa | 120 W | |
| DG200D-E092E1-01 | DG200 | 1050 m³/h | 350 Pa | 120 W | |
| DG200D-E092E3-01 | DG200 | 1300 m³/h | 500 Pa | 190 W | |
| SF133A-D092A0-01 | SF133A | 1150 m³/h | 485 Pa | 125 W | |
| SF133A-E092A1-01 | SF133A | 1150 m³/h | 485 Pa | 125 W | |
| SF133A-E092A3-01 | SF133A | 1150 m³/h | 485 Pa | 125 W | |
| SF146A-D092A0-02 | SF146A | 1080 m³/h | 580 Pa | 180 W | |
| SF146A-D092A6-02 | SF146A | 720 m³/h | 580 Pa | 80 W | |
| SF146A-E092A1-01 | SF146A | 860 m³/h | 515 Pa | 120 W | |
| SF146A-E092A3-02 | SF146A | 1080 m³/h | 580 Pa | 180 W | |
| SF146A-E092A3-CA | SF146A | 600 m³/h | 480 Pa | 180 W | |
| SF146A-E092B1-02 | SF146A | 960 m³/h | 580 Pa | 165 W | |
| SF146A-E092B3-03 | SF146A | 1180 m³/h | 700 Pa | 220 W | |
| SF146A-E092C3-34 | SF146A | 780 m³/h | 515 Pa | 88 W | |
| SF146C-D092B0-03 | SF146C | 1200 m³/h | 705 Pa | 180 W | |
| SF146C-E092B1-02 | SF146C | 1150 m³/h | 675 Pa | 165 W | |
| SF146C-E092B3-01 | SF146C | 1250 m³/h | 705 Pa | 220 W | |
| SF146D-D092A8-01 | SF146D | 1020 m³/h | 515 Pa | 165 W | |
| SF146D-E092A1-01 | SF146D | 860 m³/h | 515 Pa | 120 W | |
| SF146D-E092A1-02 | SF146D | 1050 m³/h | 585 Pa | 165 W | |
| SF146D-E092A3-01 | SF146D | 860 m³/h | 515 Pa | 120 W | |
| SF146D-E092A3-02 | SF146D | 1020 m³/h | 515 Pa | 165 W | |
| SF146D-E092B3-03 | SF146D | 1160 m³/h | 515 Pa | 220 W | |
| SF160D-E092A3-01 | SF160 | 1200 m³/h | 680 Pa | 165 W | |
| SF160D-E092B1-04 | SF160 | 1450 m³/h | 350 Pa | 220 W | |
| SF160D-E092B3-02 | SF160 | 1700 m³/h | 705 Pa | 180 W | |
| SF160D-E092B3-42 | SF160 | 1690 m³/h | 705 Pa | 240 W | |
| SF235A-E092B3-F2 | SF235 | 1650 m³/h | 880 Pa | 240 W | |
| CF100A-E072A3-01 | Duct Fan | 320 m³/h | 905 Pa | 85 W | |
| CF125A-E072A1-01 | Duct Fan-230Vac | 380 m³/h | 810 Pa | 85 W | |
| CF146-650CFM-01 | Rack-Mount Blower | 1100 m³/h | 680 Pa | 180 W | |
| CF150A-E072B3-01 | Duct Fan | 720 m³/h | 905 Pa | 115 W | |
| CF160-2000CFM-01 | Rack-Mount Blower | 3400 m³/h | 720 Pa | 360W | |
| CF160A-E072D1-01 | Duct Fan | 820 m³/h | 710 Pa | 115 W | |
| CF200A-E092D3-01 | Duct Fan | 1080 m³/h | 905 Pa | 160 W | |
| CF250A-E092D1-01 | Duct Fan | 1205 m³/h | 1010 Pa | 160 W | |
| CF315A-E092E3-01 | Duct Fan | 1750 m³/h | 1001 Pa | 220 W |
Applications
Choosing a Fan System: Commercial vs. Residential
Discover the core differences between commercial and residential ventilation systems. Learn how to select the right fan based on airflow, static pressure, and…
Range Hood Extractor Blowers & Kitchen Exhaust Fans
Dual-inlet centrifugal blowers for range hoods and kitchen ventilation — 720–1690 m³/h across 24V/48V/310V DC and 115V/230V AC, with stepless speed control and noise from 52 dB(A).It meets the EU A+++ energy efficiency requirements.
Medical & Cleanroom Ventilation Fans
Low-noise EC/DC centrifugal blowers for medical equipment, cleanrooms and laboratories — 720–1800 m³/h, IP44 options, stepless speed control and noise from 52 dB(A).
Data Center Cooling Fans & EC Centrifugal Blowers
High-static-pressure EC centrifugal blowers for server racks, CRAC/AHU and DC power systems — 1050–25000 m³/h, up to 1500 Pa, with 0-10V/PWM temperature-driven & Modbus RTU(RS485) speed control.
Selection Guides
What is the impact of blockage on the performance of an axial fan?
Catalogue fan curves are measured with a free inlet and a free outlet. Real installations block both sides — guard grilles, wall rings, coils, plenums, louvered walls and enclosure panels — and a blocked axial fan loses airflow in exactly the region where the rating promises the most. This guide gives the mechanism, a three-line calculation method, the measured clearance rules, and worked numbers for the AS910A-E150A3-01 so that a system designer can correct a catalogue curve for a real installation instead of discovering the shortfall during commissioning.
48VDC vs. 800VDC: Telecom Cabinet Fan Selection Guide
In the deployment of 5G/6G telecom networks, edge computing, and outdoor integrated cabinets, thermal management is critical for ensuring zero-downtime…
SFP (Specific Fan Power): How to Calculate It and What Counts as Good
How to calculate specific fan power from airflow and fan input power, which SFP values count as efficient for an AHU, where the losses hide, and how EC control brings the annual figure down.
EC Fans for Air Handling Units (AHU): Selection and Types
How fan sections in air handling units are arranged, why EC double-inlet centrifugal fans dominate modern AHUs, and the three parameters — airflow, external static pressure and mounting envelope — that settle the selection.
Marine Blower Selection Guide: Why Dual-Inlet Centrifugal Blowers Come First
Where blowers work on board — engine rooms, accommodation, yachts and cruising cabins — and why the dual-inlet centrifugal blower, with two suction faces and one discharge, has become the first choice for marine ventilation duty.
Mechanical Ventilation Types Explained: MVHR, ERV and PIV
A plain-language tour of every main mechanical ventilation type — exhaust-only, supply-only, balanced, MVHR, ERV and PIV — and the fan parts behind each one.
EC Fan Products Guide: Centrifugal & Axial Series
A guided tour of the complete SUNXFAN fan product puzzle: 120+ models across 25 series in two families — EC centrifugal fans (SF, BC, DG, CF duct units) and DC/EC axial fans (AF, AS, AG, 800VDC) — all built on one IE5 PMSM motor platform, with representative models like the SF146A-E092A3-02 and AG305A-D092BA-Y1.
800VDC Brushless Fans: 2026 Technical Requirements
An 800VDC brushless fan draws straight from the HVDC bus, so nothing steps down. What a 2026-spec unit must survive against: insulation, PD, EMC and derating.
How to Choose a Centrifugal Fan (CFM, Pressure)
A step-by-step guide to selecting a centrifugal blower — airflow (CFM/m³/h), static pressure (Pa), voltage, motor type and speed control, mapped to SUNXFAN's full lineup.
Comparisons
Why Hydroponics Prefer EC Backward-Curved Fans
In modern agriculture—such as hydroponics, soilless farming, and year-round indoor cultivation—precise microclimate control is the core driver of high crop…
Plastic vs Metal Volute: Which Centrifugal Fan Housing to Choose
Plastic (PA66-GF) and metal volutes differ in weight, corrosion behaviour, temperature limits and tooling cost. Here is how to choose for HVAC, range hoods and industrial ducting.
HRV vs ERV: A Guide to Heat-Recovery Ventilation Fans
What separates a heat-recovery ventilator from an energy-recovery ventilator, which climates each one suits, how to handle an ERV fan replacement, and why the EC dual-inlet centrifugal fan has become the motor of choice inside both.
Fan Manufacturers: Comparison & Selection Guide
Selecting external rotor fans requires evaluating electrical topology, bus communication, static pressure requirements, certifications, and total cost of…
EC vs AC Fans: Which Saves More Energy?
Electronically commutated (EC) fans vs traditional AC fans — efficiency, speed control, noise and total cost of ownership, with real EC models from SUNXFAN.