SUNXFAN

Centrifugal Fan

BC250 Series — Backward-Curved Centrifugal Fans

AC DC EC
BC250 Series Backward-Curved Centrifugal Fans — product photo
🔍

Applications

250 mm backward-curved centrifugal fans, 1,080–1,680 m³/h at 590–760 Pa, for air handling units, drying and filtration systems. AC (3-speed), DC and EC versions; EC adds 0-10V/PWM modulation for demand-based operation. Galvanized or PA6+GF25 impeller options, IP54.

Selection notes

The BC250 range covers 7 models between 1080–14001800 m³/h, with static pressure up to 760 Pa. Motor options are AC / DC / EC; speed is set through 3-speed, 0-10V/PWM, Modbus RTU(RS485).

For system design this means one construction principle across the whole envelope, so installations with a similar air demand can be resolved without switching fan family. For the destination market the grid is typically 110–240 V, 50/60 Hz, with CE, UL/ETL or CCC depending on destination as the compliance framework.

Model Voltage Power Airflow Noise Speed Control View Details
BC250A-A092D3-01 230 V AC 50/60Hz 175/230 W 1400/1800 m³/h 74 dB(A) 3-speed
Model Voltage Power Airflow Noise Speed Control View Details
BC250A-D092A8-01 48 VDC 160 W 1450 m³/h 71±2 dB(A) 0-10V/PWM
Model Voltage Power Airflow Noise Speed Control View Details
BC250A-E072B3-01 230 V AC 120 W 1080 m³/h 64 dB(A) 0-10V/PWM, Modbus RTU(RS485)
BC250A-E092D1-01 115 V AC 125 W 1080 m³/h 68 dB(A) 0-10V/PWM, Modbus RTU(RS485)
BC250A-E092D3-02 230 V AC 160 W 1420 m³/h 74 dB(A) 0-10V/PWM, Modbus RTU(RS485)
BC250A-E092E1-02 115 V AC 160 W 1420 m³/h 74 dB(A) 0-10V/PWM, Modbus RTU(RS485)
BC250A-E092E3-03 230 V AC 240 W 1680 m³/h 77 dB(A) 0-10V/PWM, Modbus RTU(RS485)

Compare Models

Select up to 4 models to compare detailed specifications. Each parameter row is color-coded.

FAQ

BC250A-A092D3-01

Belt-drive or direct-drive centrifugal — why is everything going direct?

Belts eat 2–5% in transmission losses, need periodic tensioning and replacement, and force alignment work at every service.

Belts eat 2–5% in transmission losses, need periodic tensioning and replacement, and force alignment work at every service. Direct-drive EC — as on this BC250 — removes all of it: the wheel sits on the motor shaft, efficiency is higher, maintenance approaches zero, and speed control comes from the motor electronics instead of a mechanical sheave change.

How do I convert these m³/h and Pa figures to CFM and inches of water?

1 m³/h = 0.589 CFM and 1 Pa = 0.00402 in.

1 m³/h = 0.589 CFM and 1 Pa = 0.00402 in. w.g. So the BC250’s 1,080–1,680 m³/h at 590–760 Pa reads as roughly 636–989 CFM at 2.4–3.1 in. w.g. Keep source units when comparing against published fan curves — rounding mid-conversion is a classic way to land on the wrong impeller.

What routine maintenance does an EC centrifugal fan need?

Very little by design: bearings are sealed and greased for life, and there is no belt or commutator to wear.

Very little by design: bearings are sealed and greased for life, and there is no belt or commutator to wear. The two jobs that matter are cleaning the impeller — dust buildup unbalances the wheel and shows up as vibration before anything else — and re-checking mounting fasteners after the first few hundred hours. A yearly clean-and-vibration pass is a sound default for continuous-duty installs.

Backward-Curved Centrifugal Fans - BC250 Series — SUNXFAN series overview card