Centrifugal Fan
DG140 Series — Single-Inlet Centrifugal Fans
Applications
Single-inlet 140 mm blowers, 380–460 m³/h at 410–460 Pa. DC (24 V / 310 V) and EC (115/230 V AC) versions share one mounting pattern — change motor technology without touching the chassis. 0-10V/PWM, IP44, galvanized or plastic impeller options.
Selection notes
The DG140 range covers 6 models between 380–460 m³/h, with static pressure up to 460 Pa. Motor options are DC / EC; speed is set through 0-10V/PWM, 3-speed, 4-speed.
For system design this means one construction principle across the whole envelope, so installations with a similar air demand can be resolved without switching fan family. For the destination market the grid is typically 110–240 V, 50/60 Hz, with CE, UL/ETL or CCC depending on destination as the compliance framework.
| Model | Voltage | Power | Airflow | Noise | Speed Control | View Details |
|---|---|---|---|---|---|---|
| DG140A-D072A6-01 | 24 V DC | 60 W | 430 m³/h | 59 dB(A) | 0-10V/PWM | |
| DG140A-D092A0-01 | 310 V DC | 100 W | 430 m³/h | 66 dB(A) | 0-10V/PWM |
| Model | Voltage | Power | Airflow | Noise | Speed Control | View Details |
|---|---|---|---|---|---|---|
| DG140A-E072A1-01 | 115 V AC | 60 W | 380 m³/h | 59 dB(A) | 0-10V/PWM, 3-speed | |
| DG140A-E072A3-01 | 230 V AC | 60 W | 380 m³/h | 59 dB(A) | 0-10V/PWM, 3-speed | |
| DG140B-E072D1-01 | 115 V AC | 100 W | 460 m³/h | 64 dB(A) | 0-10V/PWM, 3-speed | |
| DG140B-E072D3-01 | 230 V AC | 100 W | 460 m³/h | 64 dB(A) | 0-10V/PWM, 4-speed |
Compare Models
Select up to 4 models to compare detailed specifications. Each parameter row is color-coded.
FAQ
DG140A-D072A6-01
24 V or 310 V DC — which version matches my power design?
Match the blower to the bus you already have.
Match the blower to the bus you already have. This 24 V unit (430 m³/h, 410 Pa, 60 W ≈ 2.5 A) is the natural load for battery-backed sites: forklift-charging rooms, telecom shelters, 24 V cabinet cooling. The 310 V sibling (DG140A-D092A0-01) connects directly across the rectified DC link of inverter-driven appliances, heat pumps and energy-storage cabinets — one conversion stage fewer, one failure mode fewer. Both share the same mounting pattern, so the power architecture can change without redesigning the chassis.
What does clean 0-10V/PWM wiring look like on a DC blower?
Route the control pair as shielded twisted cable, grounded at one end only, and keep it away from the motor leads.
Route the control pair as shielded twisted cable, grounded at one end only, and keep it away from the motor leads. Keep the PWM signal inside the frequency range stated in the datasheet, set a minimum-speed floor so the wheel never drops below its stable band, and ramp speed changes over a few seconds instead of stepping — both inrush and acoustic surges come from abrupt steps. Never leave the input floating: an undriven input can drift to an uncommanded speed.
PP+GF or galvanized-steel impeller — which do I order?
Standard is glass-fibre-reinforced polypropylene: immune to humidity, salt air and battery-room acid mist, light on the bearings and on the motor at start-up.
Standard is glass-fibre-reinforced polypropylene: immune to humidity, salt air and battery-room acid mist, light on the bearings and on the motor at start-up. Order the galvanized-steel option when the airstream runs persistently near the +60 °C ceiling or carries grease and solvent traces, where polymers age and steel keeps its balance. Both run the same 430 m³/h / 410 Pa duty in this model.