SUNXFAN

Axial Fan

AF Axial-Fan Guard Series — Axial Fans

AC EC
AF Axial-Fan Guard Series Axial Fans — product photo
🔍

Applications

Guarded axial fans for free-air blowing and low-pressure ducted duty — condensers, dry coolers, evaporators and outdoor machine compartments. Below ~300 Pa axial geometry moves the most air per watt; this series covers 1,750–10,000 m³/h at up to 300 Pa. AC (230 V / 380 V 3-ph) and EC builds, IP54, powder-coated wire guard fitted.

Selection notes

The AF Axial-Fan Guard range covers 5 models between 1750–10000 m³/h, with static pressure up to 300 Pa. Motor options are AC / EC; speed is set through 0-10V/PWM.

For system design this means one construction principle across the whole envelope, so installations with a similar air demand can be resolved without switching fan family. For the destination market the grid is typically 110–240 V, 50/60 Hz, with CE, UL/ETL or CCC depending on destination as the compliance framework.

Model Voltage Power Airflow Noise Speed Control View Details
AF300D-A092A3-01 3-380 V AC 75 W 1750 m³/h 55 dB(A)
AF400D-A106A3-01 3-380 V AC 180 W 3600 m³/h 66 dB(A)
AF500D-A106C3-01 3-380 V AC 410 W 7050 m³/h 73 dB(A)
AF600D-A137A3-01 3-380 V AC 700 W 10000 m³/h 80 dB(A)
Model Voltage Power Airflow Noise Speed Control View Details
AF300A-E092A3-01 230 V AC 165 W 2200 m³/h 66 dB(A) 0-10V/PWM

Compare Models

Select up to 4 models to compare detailed specifications. Each parameter row is color-coded.

FAQ

AF300A-E092A3-01

Why do condensers, dry coolers and evaporators use axial fans instead of centrifugal?

Coil duty is high volume at low resistance — air crossing a finned coil typically needs only 100–300 Pa.

Coil duty is high volume at low resistance — air crossing a finned coil typically needs only 100–300 Pa. In that band an axial fan moves more air per watt and per dollar than any centrifugal. The AF series is built for exactly this window: 1,750–10,000 m³/h at up to 300 Pa, with the guard already included in the performance data.

Does the finger guard cost me airflow?

A well-designed rounded-wire guard costs typically under 5% of free-airflow, and our published curves are measured with the guard fitted — what you read is what you get. Never spec a bare fan and add a guard later: the operating point shifts and noise can rise. The guard also keeps leaves, cables and fingers out of the blade plane, a compliance requirement for accessible outdoor units.

How do I split airflow across several fans on one condenser?

Size by coil face velocity first — 2.5–3.5 m/s is the usual condenser window — then divide the total volume among the fan positions.

Size by coil face velocity first — 2.5–3.5 m/s is the usual condenser window — then divide the total volume among the fan positions. In parallel, airflows add nearly linearly, but note that two identical fans together add about 3 dB(A) and four add about 6 dB(A), which matters near night-time noise limits.

Axial Fans - AF Axial-Fan Guard Series — SUNXFAN series overview card