SUNXFAN SUNXFAN®

Centrifugal Fan

CAV EC Centrifugal blower — 600 m³/h

EC IP42
SF146A-E092A3-CA Centrifugal Fan — 600 m³/h at 480 Pa
🔍

Product Overview

SF146A-E092A3-CA is an EC centrifugal fan with a 230 Vac input, delivering 600 m³/h at up to 480 Pa, 180 W, 1200 r/min, 52±1 dB(A). Used in AHUs, fan coils, range hoods, air purifiers and ERV units. USD 50–120 FOB Nansha, MOQ 120 pcs, 25–30 days.

  • Four selectable duty curves, constant airflow under varying system resistance
  • EC motor with 0-10V/PWM speed control
  • IP42 housing, dual-inlet impeller

Technical Specifications

Category Centrifugal Fan
Model SF146A-E092A3-CA
Motor Type EC
Airflow 600 m³/h
Max Static Pressure 480 Pa
Voltage 230 V AC
Power 180 W
Current 0.78 A
Speed 1200 r/min
Noise 52±1 dB(A)
Protection Class IP42
Working Temperature -25 °C ~ +50 °C
Impeller Material PA6+GF25%
Bearing Type NSK ball bearing
Speed Control 0-10V/PWM

Data updated 2026-10

Ordering Information

MOQ (Min. Order Qty) 120 PCS
FOB Price FOB Nansha Guangzhou
Reference price US$50–120
Lead Time 25-30 days
Sample Sample available
Payment Terms TT
Shipping Port Nansha Guangzhou OR Yantian Shenzhen

Performance Curves

01002003004005006000100200300400500 Airflow (m³/h) Static pressure (Pa)
PWM 100% / Vsp 10.0VPWM 65% / Vsp 6.5VPWM 40% / Vsp 4.0VPWM 20% / Vsp 2.0V

Dimensions

CAV EC Centrifugal blower — 600 m³/h — Dimensions

Special Remarks

Constant Air Volume (CAV):can customize according to your CAV system requirements (air volume, pressure...)

Applications

Built for constant-airflow duty against a varying system resistance: laboratory fume hoods and VAV terminal boxes that must hold face velocity within ±10 % as the sash moves, cleanroom and pharmaceutical FFU / HEPA terminal housings whose airflow must not drift as filters load up, spray booths and dust collectors whose media resistance rises through a shift, drying and curing tunnels that need a fixed process-air volume, and greenhouse CO₂ enrichment where the air change rate itself is the setpoint. Commissioning engineers select one of the four PWM/Vsp duty curves to set the design airflow (600 / 450 / 300 / 180 m³/h) and the EC motor holds it without re-balancing the ductwork. Typical installations run between 100 and 300 Pa system resistance; beyond that the operating point climbs the steep branch of the curve and airflow collapses toward the 480 Pa shut-off point.

Product dataSheets (PDF Download)

View Product dataSheets (PDF) PDF · EC·Centrifugal fan:SF146A-E092A3-CA Product dataSheets

Compliance & related pages