Applications
Telecom and ICT Cabinet Cooling
In short: 5 series (7 models) cover 540–9,000 m³/h, up to 1550 Pa static pressure for Telecom and ICT Cabinet Cooling.
Telecom cabinets sit outdoors, run on a 48 VDC bus and cannot afford a fan failure. The range covers 48 VDC and 800 VDC models with wide input range, IP54 protection and bearings rated for continuous high-temperature operation.
- Families
- 5
- Models
- 7
- Airflow
- 540–9,000 m³/h
- Motor types
- DC
Typical applications
- Outdoor telecom and base-station cabinets.
- 48 VDC powered radio and transmission equipment.
- Edge data centers and 5G small cells.
- 800 VDC power shelves in high-density ICT racks.
How to choose
Telecom equipment runs on a 48 VDC bus, so choose a fan whose operating range covers 36–60 VDC without derating; for 800 VDC racks confirm the insulation class before specifying.
Industry criteria, series picks and evidence
Telecom and ICT cabinets are DC-native and outdoor-rated, so the fan is chosen by bus voltage, ambient range and serviceability.
| Criterion | Typical value | Why it drives the selection |
|---|---|---|
| Bus voltage | 48 V DC or 800 V DC | Direct operation, no inverter stage |
| Ambient range | −40 °C to +65 °C | Outdoor cabinets and shelters |
| Ingress protection | IP54 / IP55 | Dust and water exposure at the cabinet |
| Control | 0-10V/PWM | Speed follows cabinet temperature |
Recommended series
Recommended series
Other applications
Related engineering guides
Frequently asked questions
- How do I choose a fan for Telecom and ICT Cabinet Cooling?
- Telecom equipment runs on a 48 VDC bus, so choose a fan whose operating range covers 36–60 VDC without derating; for 800 VDC racks confirm the insulation class before specifying.
- Which models, airflow ranges and motor types are available for Telecom and ICT Cabinet Cooling?
- 7 models in 5 series, airflow 540–9,000 m³/h, motor types DC. Full parameters are listed on each series page.
- Which certifications apply to the fans used in Telecom and ICT Cabinet Cooling?
- ISO 9001:2015 covers motor design and production; CE (LVD), RoHS, REACH and CCC test reports are available for the motors. UL documents are provided on request.
- What are the MOQ, sample and lead time for Telecom and ICT Cabinet Cooling orders?
- MOQ, sample policy and lead time depend on model and quantity. Send the model and annual volume and we will confirm within one business day.
Need a selection check?
Send airflow, static pressure, voltage and ambient conditions — our engineers confirm the model and reply within one business day.