Data Center Cooling Fans

In short: 6 series (33 models) cover 750–29,000 m³/h, up to 1550 Pa static pressure for Data Center Cooling Fans.

Data-center cooling has moved from room-level CRAC units to in-row, rack and direct-to-chip systems, and every step raises the pressure the fan must overcome. SUNXFAN supplies EC centrifugal blowers for coil-and-filter paths, rack-mount blowers for cabinets and 800 VDC axial fans for megawatt AI racks.

Families
6
Models
33
Airflow
750–29,000 m³/h
Motor types
AC / DC / EC

Typical applications

How to choose

Start from coil pressure drop and the redundancy scheme: N+1 units usually carry 60–70 % of total flow each, so size on the part-load curve rather than the free-air point.

Industry criteria, series picks and evidence

Cooling duty is continuous and redundancy-driven, so the fan is chosen on pressure at the operating point, controllability and service life — not on peak airflow alone.

Criterion Typical value Why it drives the selection
Static pressure at duty 300–700 Pa Coil, filter and duct resistance in series
Airflow per module 1,000–3,000 m³/h Matched to the IT load and ΔT design
Control 0-10V/PWM, Modbus RTU Speed follows rack or return-air temperature
Duty cycle 24/7, 8,760 h/yr Bearing life and partial-load efficiency dominate

Recommended series

Recommended series

Other applications

Related engineering guides

Frequently asked questions

How do I choose a fan for Data Center Cooling Fans?
Start from coil pressure drop and the redundancy scheme: N+1 units usually carry 60–70 % of total flow each, so size on the part-load curve rather than the free-air point.
Which models, airflow ranges and motor types are available for Data Center Cooling Fans?
33 models in 6 series, airflow 750–29,000 m³/h, motor types AC / DC / EC. Full parameters are listed on each series page.
Which certifications apply to the fans used in Data Center Cooling Fans?
ISO 9001:2015 covers motor design and production; CE (LVD), RoHS, REACH and CCC test reports are available for the motors. UL documents are provided on request.
What are the MOQ, sample and lead time for Data Center Cooling Fans orders?
MOQ, sample policy and lead time depend on model and quantity. Send the model and annual volume and we will confirm within one business day.